Concrete repair in an underground car park in Barcelona
In the underground car park of a corporate building in Barcelona, the ceiling had spalling with corroded reinforcement, and the slab and floor had open cracks and joints with leaks. It was repaired by zones, with the car park in use, following the principles of EN 1504. For data protection reasons we do not publish the owner or the address.
Why concrete spalls in a car park
Carbonation and chlorides reach the reinforcement, the steel rusts, expands and pushes the cover off. Filling the spall with mortar without treating the bar does not work: within a few years it falls again. The repair has to tackle the cause.
How we work: from enquiry to handover
On every project we take on whatever is needed, a single phase or the whole process:
- Technical enquiry. We receive photos, drawings and the problem, and reply with an initial assessment.
- Consulting and diagnosis. Site visit, testing and choice of the right system for the substrate and use.
- Specification and fixed-price quote for materials and execution.
- Execution by an approved applicator from our network, trained and approved by the system manufacturer.
- Site management and quality control: substrate, moisture, thickness, curing and detailing.
- Finishing, final documentation and handover.
Double guarantee: the manufacturer backs that the installed system meets its standards, and we guarantee it has been applied correctly. That is why our repairs, waterproofing and floors last for years.